Human Galectin 9 ELISA Kit

Human Galectin 9 ELISA Kit For the quantitative in vitro determination of Human Galectin 9 concentrations in serum - plasma - celiac fluid - tissue homogenate - body fluid FOR LABORATORY RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. This package insert must be read in its ELISAENZYME LINKED IMMUNOSORBENT ASSAYINTENDED USE AND TEST PRINCIPLEThis Galectin 9 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of The color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of Galectin 9 in the sample, the Galectin 9 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow The operator to produce a standard curve of Optical Density versus Galectin 9 concentration. The concentration of Galectin 9 in the Samples is then determined by comparing the OD of the samples to the standard curve. SAMPLE COLLECTION AND STORAGESSerum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4°C before centrifugation for 20 minutes at approximately 2000 ×g. Remove serum and assay immediately or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cyclesPlasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8°C within 30 minutes Avoiding freeze-thaw cycles.Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20°C. cycles.Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.MATERIALS REQUIRED BUT NOT SUPPLIED1. 37 °C incubator2. Standard microplate reader capable of Measuring absorbance at 450 nm3. Precision pipettes, disposable pipette tips and Absorbent paper4. Distilled or deionized waterREAGENTS PROVIDED All reagents provided are stored at 2-8°C. Refer to the expiration date on the label. Name 96 determinations 48 determinationsMicroelisa stripplate 12* 8strips 12*4stripsStandard(6 vial) 0.5ml/vial 0.5ml/vialSample diluent 6.0ml 3.0mlHRP-Conjugate reagent 10.0ml 5.0ml20X Wash solution 25ml 15mlChromogen Solution A 6.0ml 3.0mlChromogen Solution B 6.0ml 3.0mlStop Solution 6.0ml 3.0mlClosure plate Membrane 2 2User manual 1 1Sealed bags 1 1Note: 1. Standard concentration was followed by: 160, 80, 40, 20, 10, 5pg/mL.2. If samples generate values ​​higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.PRECAUTIONS1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents. 3. Do not use kit components beyond their expiration date. 4. Use only deionized or distilled 5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided. 6. Use fresh disposable pipette tips for each transfer to avoid 8. Disumable plasma must be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that Products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed. 9. All samples should be disposed of in a 11. The Waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal. 11. Substrate Solution is easily contaminated. If bluish prior to use, do not use. 12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame. 13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25° C).REAGENT PREPARATION AND STORAGEWash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C. ASSAY PROCEDURE1. Prepare all reagents Before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn't add anyting.3. Add 100μl of HRP- Conjugate reagent to standard wel Lls and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.4. Wash the Microtiter Plate 4 times.Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, Note: Hold the sides of the plate frame firm when washing the plate to assure that all strips remain securely in frame. Automated Washing - Aspirate all wells, then wash Essentials brushes to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.6. Add 50μl Stop Solution to each well. The color In the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing. 7. Read the Optical Density (OD) at 450 nm using a The standard curve is generated by plotting the average OD (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis. 2. First, calculate the mean OD value for each standard and sample. All OD Values ​​are subtracted by the mean value of the balnk well before result interpretation. Standard cur To determine the amount in each sample, first locate the OD value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the 4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.5. Intra-assay CV (%) and Inter-assay CV (%) are less than 15%.6. Assay range: 5 pg/mL – 160 pg/mL.7. Sensitivity: The minimum detectable dose of Human Galectin 9 is typically less than 1.0 pg /mL.8. Cross-reactivity: This assay recognizes recombinant and natural Human Galectin 9 No significant cross-reactivity or interference was observed. 9. Storage: 2-8 ° C (Use frequently); six months (-20 ° C). 10. QUOTE READ ONH;

Frisbee & Flying Discs

Welcome to our Flying Discs pages. Different from many other industries, for Frisbee, designing could be one of the most important steps for a project. Whether the sample could be made lively and cost-effective may lead the project success or failure directly. So designing ability could be the core competitiveness for a Plush Toys company. We're pride ourselves on our design team who has 10+ years experience in the toy industry. We not only will make it identical to your specifications, we will also find a faster and better way to save you cost in Frisbee & Flying Discs production.


Our Frisbee Advantage
Low MOQ: It can meet your promotional business very well.
OEM Accepted : we design and produce according to your idea.
Good Service : We treat clients as friends.
Good Quality :We have strict quality control system .Good reputation in the market.
Fast & Cheap Delivery: We have big discount from forwarder (Long Contract).

Sample Ready
Any size,material,color and printing for Frisbee & Flying Discs is workable.
We will charge you on the sample fee as less as we can, even sometimes a free sample is possible. However, you have to pay us the cost of courier by express like: DHL, TNT, UPS and FEDEX.
Sample will be ready in 3-5days.

Why Choose us-Best Service
High quality & competitive price to be provided.
We do reply within 24 hours, welcome your e-mails anytime.
OEM is welcome, just give us your specification or pictures, We can do as per your artwork and also we can design for you.
We can be based on your need to select your fabric, size and printing.

Frisbee & Flying Discs

Flying Discs,Rubber Dog Frisbee,Soft Dog Frisbee,Dog Frisbee

Ningbo Movepeak Pet Supplies Co.,LTD. , https://www.pet-supplies-factory.com

Posted on